TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
The vacuum does not start No power Check the cable, plug and socket
The boiler filling pump can be
heard working continuously
Air in the boiler circuit. Switch off the equipment, let it cool
down and repeat the procedures of
chapters 3 and 4.
The suction power drops The upholstery nozzle, the
flexible tube or the stiff suc-
tion tube are clogged.
The HEPA filter is exhausted
Clen the filter and remove any
obstruction from the tubes and ac-
cessories.
Follow the instructions in the para-
graph headed “WASHABLE HEPA
FILTER”.
Water is spilled while sucking up
liquids.
Float device clogged Clean the “EcoActive Filter” water fil-
ter assembly.
The vacuum cleaner switches off
during suction and the four indi-
cator lights flash.
The liquid level in the con-
tainer is too high
The selected power is too
high for the type of surface
Before resuming your cleaning opera-
tions, proceed as illustrated in the sec-
tion “Emptying and cleaning the dirt
container”
Push the switch (1), disconnect the
supply cable from the mains and keep
the appliance disconnected at least 30
seconds to allow the safety device to
reset
LECOASPIRA TURBO & ALLERGY - M0S10127 - 1S01:Layout 1 04/05/2012 10.59 Pagina 151